Description
This series is a single-phase low voltage (48V) hybrid inverter that enables enhanced energy independence and maximizes self-consumption through export limit feature and “time of use” function.
Model | SUN-8K-SG01LP1-EU | |
Battery Input Data | ||
Battery Type | Lead-acid or Lithium-ion | |
Battery Voltage Range(V) | 40-60 | |
Max.Charging Current(A) | 190 | |
Max.Discharging Current(A) | 190 | |
Charging Strategy for Li-ion Battery | Self-adaption to BMS | |
Number of battery input | 1 | |
PV String Input Data | ||
Max. PV Access Power (W)
|
16000 | |
Max. PV Input Power (W)
|
10400 | |
Max. PV Input Voltage (V
|
500 | |
Start-up Voltage(V) | 125 | |
MPPT Voltage Range(V) | 150-425 | |
Rated PV Input Voltage (V)
|
370 | |
Max Input Short-Circuit Current(A) | 34+34 | |
Max Operating PV Input Current(A) | 26+26 | |
No.of MPP Trackers/No.of String Per MPP Tracker | 2/2+2 | |
AC Input/Output Data | ||
Rated AC Input/Output Active Power(W) | 8000 | |
Max AC Input/Output Apparent Power (VA) | 8800 | |
Peak Power (off-grid)(W) | 2 times of rated power,10s | |
Rated AC Input/Output Current(A) | 36.4/34.8 | |
Max AC Input/Output Current(A) | 40/38.3 | |
Max Continuous AC Passthrough (grid to load)(A) | 50 | |
Rated Input/Output Voltage/Range(V) | 220/230 0.85Un-1.1Un | |
Grid Connection Form | L+N+PE | |
Power Factor Adjustment Range
|
0.8 leading to 0.8 lagging
|
|
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |
Total Current Harmonic Distortion THDi | <3% (of nominal power) | |
DC Injection Current | <0.5%ln | |
Efficiency | ||
Max Efficiency | 97.60% | |
Euro Efficiency | 96.50% | |
MPPT Efficiency | >99% | |
Equipment Protection | ||
Integrated
|
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
|
|
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
|
||
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
|
||
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
|
||
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
|
||
Surge Protection Level | TYPE II(DC),TYPE II(AC) | |
Interface | ||
Communication Interface | RS485/RS232/CAN | |
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) | |
General Data | ||
Operating Temperature Range |
-40 to +60℃, >45℃ Derating
|
|
Permissible Ambient Humidity | 0~100% | |
Permissible Altitude | 2000m | |
Noise | <30 dB(A) | |
Ingress Protection(IP) Rating | IP 65 | |
Inverter Topology | Non-Isolated | |
Over Voltage Category | OVC II(DC),OVC IV(AC) | |
Cabinet size(W*H*D)[mm] | 420×670×233(Excluding connectors and brackets) | |
Weight[kg] | 30 | |
Warranty | 5 Years/10 Years | |
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | ||
Type Of Cooling | Intelligent air cooling | |
Grid Regulation |
IEC 61727, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
|
|
OVE-Richtlinie R25, G99, VDE-AR-N 4105 | ||
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |